Korean Journal of Nuclear Medicine Technology (Korean J Nucl Med Technol)

Open access, Peer Reviewed

Indexed in KCI, DOAJ

pISSN 1229-9901
eISSN 2982-8406

Original article

Utility of an Electric Lead-Shielded Cart for Radioactive Waste Transport

Department of Nuclear Medicine, National Cancer Center

Correspondence to Ho-Yong Choi, Department of Nuclear Medicine, National Cancer Center, 323 Ilsan-ro, Ilsandong-gu, Goyang-si, Gyeonggi-do 10408, Republic of Korea. Tel: +82-31-920-0171, E-mail: h6993@ncc.re.kr

Volume 30, Number 2, Article 23, November 2026. Korean J Nucl Med Technol 2026;30(2):23. https://doi.org/10.12972/kjnmt.2026.30.2.23
Received on October 02, 2026, Revised on October 27, 2026, Accepted on October 30, 2026, Published on November 30, 2026.
This is an Open Access article distributed under the terms of the Creative Commons CC BY 4.0 license (https://creativecommons.org/licenses/by/4.0/) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Abstract

Purpose: Radioactive waste generated during radioiodine therapy must be transported safely while minimizing workers’ radiation exposure and physical burden. Increasing lead shielding lowers the ambient dose rate but also increases cart weight, and therefore the effort required to push a manual cart. Motorized propulsion may allow thicker shielding to be applied without imposing this additional effort on the worker. This study therefore aimed to evaluate the clinical utility of an electric lead-shielded cart by comparing its shielding effectiveness, working posture, and transport efficiency with those of the manual lead-shielded cart previously used at our institution. Materials and Methods: Thirty batches of radioactive waste were collected from patients who received at least 3.7 GBq (100 mCi) of I-131 evaluated between March 4 and June 26, 2026. Ambient dose rates were measured at 50 and 100 cm from the center before shielding and from the cart handle end after shielding. Ten measurements over 5 minutes were averaged after stabilization, and background-corrected shielding effectiveness was compared between carts using paired t-tests. Working posture was assessed with the Rapid Entire Body Assessment, and transport efficiency was evaluated by measuring round-trip travel time once for each cart along the same route. Results: At a measurement distance of 100 ㎝, shielding effectiveness was 53.90±20.47% for the manual cart and 97.09±2.57% for the electric cart, a difference of 43.20 percentage points (95% confidence interval, 35.46-50.93; P<0.001). At 50 ㎝, the corresponding values were 55.35±19.64% and 96.78±2.20%, a difference of 41.43 percentage points (95% confidence interval, 33.87-49.00; P<0.001). The final Rapid Entire Body Assessment score was 3 for the manual cart and 1 for the electric cart, indicating low and negligible risk levels, respectively. Round-trip travel time was 1,140 seconds for the manual cart and 1,120 seconds for the electric cart, a reduction of 20 seconds or 1.75%. Conclusion: The electric lead-shielded cart provided markedly higher shielding effectiveness and a lower working posture risk level than the manual lead-shielded cart, whereas the reduction in travel time was minimal. These findings suggest that the electric lead-shielded cart is clinically useful mainly for lowering the ambient dose rate during transport and for reducing the postural burden on workers, rather than for shortening transport time.
Keywords

Radioactive waste transport, Radiation shielding, Rapid entire body assessment

Section