Korean Journal of Nuclear Medicine Technology (Korean J Nucl Med Technol)

Open access, Peer Reviewed

Indexed in KCI, DOAJ

pISSN 1229-9901
eISSN 2982-8406

Original article

Consideration for Setting Reference Range for Adrenocorticotropic Hormone Test according to Blood Collection Time

Department of Nuclear Medicine, Asan Medical Center, Seoul, Korea

Correspondence to Sun-Ho Lee, Department of Nuclear Medicine, ASAN Medical Center, Seoul, 05505, Korea, Tel: +82-02-3010-4573, Fax: +8202-3010-4588, E-mail: sunho@amc.seoul.kr

Volume 27, Number 1, Article 8, May 2023. Korean J Nucl Med Technol 2023;27(1):8. https://doi.org/10.12972/kjnmt.20230008
Received on December 07, 2022, Revised on March 24, 2023, Accepted on March 28, 2023, Published on May 31, 2023.
Copyright © 2023 Author(s). This is an Open Access article distributed under the terms of the Creative Commons CC BY 4.0 license (https://creativecommons.org/licenses/by/4.0/) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Abstract

Purpose: The reference range described in Adrenocorticotropic Hormone reagent used in our laboratory is 10-60 pg/mL at 8 a.m. to 10 a.m., and 6-30 pg/mL at 8 p.m. to 10 p.m. However, in the case of outpatients, blood is mainly collected between 10 a.m. and 6 p.m., accounting for 57.8% of the total. Therefore, This study is intended to help make a more accurate diagnosis by reevaluating the reference range provided by the manufacturer of the Adrenocorticotropic Hormone reagent and setting split-timed reference range. Materials and Methods: The patients collected blood before 10 a.m. were group A (68 people), and the patients collected blood after 10 a.m. were set to group B (80 people). A T-test was performed between groups to test their significance. And it was confirmed whether it was necessary to set the gender classification as a subgroup. The method of setting the reference range was calculated by the Bayesian’s method and the Hoffmann’s method. Results: The reference range of Group A was 8.6 to 60.6 pg/mL by the Bayesian’s method, and the Hoffmann’s method was 3.6 to 61.3 pg/mL. The reference range of Group B was 6.9 to 50.5 pg/mL when applying the Bayesian’s method, and the Hoffmann method’s was 2.3 to 48.9 pg/mL. Conclusion: This study was concluded that it was necessary to set the split-timed reference range. Through this study, the later the blood collection time, the lower the level of Adrenocorticotropic Hormone, indicating that blood collection time is important for patients with clinical significance. If a large number of subjects are selected and supplemented in the future, it is believed that systematic and accurate reference range can be set.
Keywords

Adrenocorticotropic Hormone, T-Test, Bayesian’s Method, Hoffmann’s Method

Section